High‑Rupturing Capacity HRC Fuses for DC Systems

From 10A to 2000A · DC up to 1500V  · Breaking Capacity up to 250kA .

UL 248, IEC 60269, BS88 compliant

Trusted by Industry Leaders

HRC Fuse Application Scenario

  • The above products are only examples. There are many other products not listed.
  • In addition to standard products, we also provide customers with customized solutions to meet specific application needs.

Explore Our Top HRC Fuse Models

Pyrofuse SPF-4A

Breaking capacity:16kA @ 1000VDC (40μH)

Rated Voltage: 1000VDC

Rated Current: 400A

Triggering current: ≥1.75A@0.5ms

Trigger method: Internal & External Trigger

No Gas Release

SEV-59F/59FI

Breaking capacity: 250kA

Rated voltage: DC1500V

Rated current: 100-630A

Standards:  IEC60269, GB/T13539, UL248

In compliance with:
UL

SES-159EI

Breaking capacity: 150kA

Rated voltage: DC1500V

Rated current: 1250-3000A

Standards: IEC60269 GB/ T13539

In compliance with:
ROHS
TUV
CE

SEV-43F

Breaking capacity: 100kA

Rated voltage: DC1000V

Rated current: 250-1000A

Standards: UL248-1, UL248-13 and IEC60269-4

In compliance with:
ROHS
TUV
CE
CCC

HRC Fuse Series & Specification Ranges

SES Series

Breaking capacity: 20kA ~ 250kA

Rated Voltage: 250V ~ 1500V DC

Rated Current: 30A ~ 3000A

Standards: IEC60269, UL248,  EN20269, ISO8820 and GB/T13539

Model Image Voltage Current Class Standards Breaking Capacity
SES-16H DC250–1000V 30–200A gR BS88-4, IEC60269-4,GB/T13539 20–25kA
SES-30JC SES-30JC DC500V 300–550A gR BS88-4, IEC60269-4,ISO8820,GB/T13539 50kA
SES-38JM SES-38JM DC250V 250–850A gR EN20269-4, GB/ T13539.1, GB/T 13539.4 50kA
SES-00N SES-00N DC500V 160–630A gR UL248-13, BS88-4, IEC60269-4 50kA
SES-43F SES-43F DC1000V 100–400A gR BS88-4, IEC60269-4,GB/T13539 50kA
SES-51F SES-51F DC250V 200–700A gR GB/T13539.1,GB/T13539.4 50kA
SES-59F / 59FI DC1000V 250–800A gR UL248-13, BS88-4, IEC60269-4 100kA
SES-59F / 59FI SES-59FI DC1500V 100–630A gR UL248-13, BS88-4, IEC60269-4 250kA
SES-105F SES-105F AC2000V 630–1250A gR UL248-13, BS88-4, IEC60269-4 100kA
SES-159E / 159EI DC1500V 1250–3000A gR BS88-4, IEC60269-4, GB/T13539 150kA

SEV Series

Breaking capacity: 10kA ~ 50kA

Rated Voltage: 250V ~ 1000V DC

Rated Current: 10A ~ 900A

1465, IEC60269, GB/T13539, QC/T1174 a, GB/T1353, UL248

Model Image Rated Voltage Rated Current Class Standards Breaking Capacity
SEV-10H DC250–1000V 15–63A aR BS88-4, IEC60269-4,ISO8820,JASOD622 20–30kA
SEV-10P DC500–1000V 10–63A gR ISO8820,JASOD622 10–20kA
SEV-10PD DC500V 10–30A gR ISO8820,JASOD622 15kA
SEV-16H DC250–1000V 30–200A gR BS88-4, IEC60269-4,ISO8820,JASOD622 20–25kA
SEV-24J DC250–500V 100–400A gR ISO8820,JASOD622 20kA
SEV-30JC DC500V 175–500A gR BS88-4, IEC60269-4,ISO8820,JASOD622 20kA
SEV-31J DC1000V 125–200A gR ISO8820,JASOD622 20kA
SEV-37J DC500V 300–630A gR ISO8820,JASOD622 20kA
SEV-38J DC750V 250–550A gR UL 248-13,BS88-4, IEC60269-4,ISO8820 50kA
SEV-43F DC750–1000V 100–630A gR BS88-4, IEC60269-4,ISO8820,JASOD622 50kA
SEV-43EI DC750–1000V 100–630A gR BS88-4, IEC60269-4,ISO8820,JASOD622 50kA
SEV-50JM DC1000V 600–900A gR BS88-4, IEC60269-4,ISO8820,JASOD622 20kA
SEV-59F DC1000V 250–1000A gR BS88-4, IEC60269-4,ISO8820,JASOD622 100kA
SEV-64JM DC1000V 400–800A gR GB/T13539.1 GB/T13539.4 25kA

Pyrofues Series

Breaking Capacity: 1.2kA ~ 16kA @150V~1000VDC

Rated Voltage: 32 – 1500 VDC

Rated Current: 300-400 A

No Gas Release

Models Image Rated Voltage Rated Current Size (mm) Weight (g) Trigger Method Max. Breaking Capacity
SPF-1 DC150V 300A 30×22×42 ≤60 Triggered by external signal 32V/2kA/60μH
150V/1.2kA/60μH
SPF-2 DC500V 400A 42×42×68 ≤190 Triggered by external signal 400V/10kA/15μH
500V/5kA/20μH
SPF-2H DC930V 400A 42×42×75 ≤210 Triggered by external signal 930V/12kA/25μH
930V/3kA/140μH
SPF-2L DC930V 400A 42×42×63 ≤180 Triggered by external signal 930V/12kA/15μH
500V/13kA/15μH
SPF-3 DC1000V 400A 50×50×79 ≤230 Triggered by external signal 1000V/16kA/20μH
SPF-4A DC1000V 400A 70×50×83 ≤340 Triggered by internal and external signal 1000V/16kA/40μH
We Know What Matters to You

Challenges When Sourcing HRC Fuses Supplier?

Does It Fit My System?

The right answer isn’t just “Yes”—It’s “Let’s make sure it does.”

 

We deliver custom-engineered, verified, and application-ready solutions that truly fit.

Will It Truly Protect?

Yes—Because we test for real faults, not just lab specs.

 

Your safety depends on more than a part. We deliver protection that works where failure isn’t an option.

Always There for Me?

Support isn’t just about promises—Its about actions when you need them most.

 

From first reply to final delivery, were built to keep your project moving.

image11.webp
WHO WE ARE

DC‑Rated HRC Fuses — Ultra‑Fast, Ultra‑Safe

Chauron Technology specializes in high-rupturing capacity (HRC) fuses engineered for today’s most demanding DC applications—including energy storage systems, electric vehicles, charging infrastructure, and data centers. Our advanced fuse designs support breaking capacities up to 250kA and operating voltages up to 1500VDC, ensuring fast, safe interruption of fault currents in critical power systems.

 

Founded in 2018 and led by Dr. Dai—a member of the National Fuse Standards Committee—Chauron is committed to raising the benchmark for circuit protection. With two smart manufacturing facilities and a CNAS-accredited test lab, we deliver precision-engineered HRC fuses that meet IEC, UL, and BS standards, trusted by OEMs and integrators across the new energy industry.

Why Top Industry Brands Choose Chauron?

01

Standards Leadership

We Help Shape Industry Standards

Our founder Dr. Dai plays a key role in shaping China’s fuse standards—positioning our solutions to meet future regulatory demands and streamline your path to certification.

1 +
Expert Employees
1 w+
Fuse Sales

02

CNAS Certified Lab

Our Laboratory is CNAS-Accredited

Performing in-house testing and certification ensures fast, reliable, and fully verified fuse solutions—eliminating the need for external validation.

03

Fully Automated Manufacturing

We Build with Automation

We operate two fully automated factories—ensuring consistent quality, stable processes, and flexible production for reliable, on-time delivery at any scale.

04

National High-Tech CertifiedC

We’re Nationally Certified

Officially recognized as a National High-Tech Enterprise—backed by strong R&D and innovation capabilities to ensure long-term reliability and trusted technical solutions.

Three Steps to Cooperation

We make it simple to get started. From technical consultation to sample testing and final delivery, we guide you every step of the way.

SPF 2
1

Step 1: Technical Alignment & Sample Validation

The test waveform (930V12kA25μH)
2

Step 2: Trial Order & Supply Evaluation

chuaron testing center
3

Step 3: Mass Production & Long-Term Partnership

What Our Clients Say

We'll reply within 24h. Your privacy is protected

Get Free Quotes

Download Product Catalog

Find the right product in minutes.

Get the DC Fuse Catalog

Get the DC Fuse Catalog